-40%

SPO2 Simulator Blood Pressure NIBP Simulator ECG Patient Simulator,CONTEC US

$ 210.67

Availability: 20 in stock
  • Brand: CONTEC
  • Intended Use/Discipline: Biological Laboratory
  • All returns accepted: Returns Accepted
  • Return shipping will be paid by: Buyer
  • Condition: New
  • Refund will be given as: Money Back
  • Country/Region of Manufacture: United States
  • MPN: 69450401
  • Item must be returned within: 60 Days

    Description

    Please choose the parameter you need:
    MS100 SpO2 Simulator
    MS200 NIBP Simulator
    MS400 Patient Simulator(ECG RESP TEMP IBP)
    SPO2 SIMULATOR MS100
    Brief Introduction
    MS100 SpO2 Simulator is a kind of Separated SpO2 simulator, small and light. It can perform a series of tests for the oximeter by simulation means, and gives cognizance of veracity about the oximeter.
    Because the oximeter manufacturer may use different R-curves, some R-curves used abroad currently have been embedded.
    Features
    ◆ Separated connection between simulator probe and host, operation and test are more convenient.
    ◆ 262K color and 320*240 TFT, adjustable brightness level.
    ◆ Film key-press, makes the operation more comfortable.
    ◆ Power with chargeable lithium battery, can display the charge information of battery.
    ◆ Key volume, can open or close.
    Main Functions
    ◆ Oxygen saturation simulation;
    ◆ Pulse rate simulation;
    ◆ Patient state simulation preset;
    ◆ Can test the reaction time of device;
    ◆ Can simulate the SpO2 and pulse rate under different amplitude;
    ◆ Can test the performance of device under different interference source;
    ◆ Can select different R-curve.
    Main Parameters
    ◆ SpO2
    Measuring range: 35%~100%
    Resolution:1%
    Error: When SpO2 is 75%~100%, the error is the larger between ±2% and ±P(P denotes the precision of the tested oximeter); when SpO2 is 74%~50%, the error is the larger between ±2% and ±P; no define when SpO2 is less than 50%.
    ◆ Pulse rate
    Measuring range:25bpm~250bpm
    Resolution:5bpm
    Error:1%±1bpm
    ◆ Amplitude
    Measuring range:0.000%~20.000%
    Resolution:1% for 1.000%~20.000%; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%.
    ◆ Patient state
    24 conditions presetting and 8 conditions as default after start. The number of condition can be adjusted by Motion level setup.
    ◆ Voltage
    DC 3.6V~4.2V
    ◆ Power Supply
    Voltage 3.7 rechargeable lithium battery × 1
    ◆ Battery working life
    Charge and discharge no less than 500 times.
    Accessories
    ◆ A  MS100 user manual
    ◆ A  5.0V adaptor
    NIBP SIMULAOR MS200
    Product overview
    MS200 NIBP Simulator is a multi-purpose test instrument for use with oscillometric Non-Invasive Blood Pressure(NIBP) Monitors. The appearance is concision ,operation is simple and convenient,with its internal pump, the Simulator can generate pressures up to 400 mmHg (53.3 kPa).The Simulator provides dynamic blood pressure simulations, static pressure calibration, automated leak testing, and pressure relief valve testing.You can quickly and exact analyse different NIBP Monitors.
    Main features
    Provides pressure gauge testing,pressure leak testing,relief valve testing functions .
    Build-in pump provides pressure source with leak and pressure relief tests
    NIBP simulations for both arm and wrist cuffs.
    Provides adult,neonate, eight variations patients conditions,user-defined simulations.
    Provides arrhythmias,respiratory artifact simulations.
    Built-in air chamber to simulate adult and neonate cuff.
    65k colors,4.3" LCD display.
    Technical index
    ►Pressure measurement
    Units:mmHg,kPa,cmH2O,inH2O,psi
    Range:0mmHg-400mmHg
    Resolution:1 mmHg,0.1 kPa,1 cmH2O,1 inH2O,0.1 psi
    Accuracy:0-300 mmHg:±0.5% of reading ±1 mmHg;
    301-400 mmHg:±2%of reading
    ►Pressure Generator
    Static Pressure Range:50 mmHg-400 mmHg
    Resolution:1mmHg
    Difference between target pressure and actual pressure :±10 mmHg from 100-400 mmHg with a minimum volume of 300 cc
    ►Internal leak rate
    <2 mmHg per minute, with a minimum volume of 300 cc
    ►Pressure Leak Test
    Pressure generate up to 400 mmHg (53.3 kPa) with internal pump.The screen always show the peak pressures and the real-time pressures.Leak rate displayed after 10 seconds.
    ►Pressure Relief Test
    Pressure generate up to 400 mmHg (53.3 kPa) with internal pump,Displays peak pressure.
    ►Standard BP Simulations
    Preset blood pressure:
    1#: BP: 120/80(93) HR: 80 Pulse Volume: 0.68
    2#: BP: 150/100(116) HR: 80 Pulse Volume: 0.65
    3#: BP: 200/150(166) HR: 80 Pulse Volume: 0.60
    4#: BP: 255/195(215) HR: 80 Pulse Volume: 0.55
    5#: BP: 60/30(40) HR: 80 Pulse Volume: 0.75
    6#: BP: 80/50(60) HR: 80 Pulse Volume: 0.71
    7#: BP: 100/65(76) HR: 80 Pulse Volume: 0.69
    ►Patient Conditions
    BP Simulations
    Healthy: BP: 120/80(93) HR:75 Pulse Volume: 0.68
    Weak Pulse: BP: 110/80(90) HR:95 Pulse Volume: 0.50
    Mild Exercise: BP: 140/90(106) HR:120 Pulse Volume: 1.00
    Strenuous Exer: BP: 140/90(106) HR:162 Pulse Volume: 1.40
    Obese: BP: 120/80(93) HR:90 Pulse Volume: 0.50
    Geriatric: BP: 150/110(123) HR:95 Pulse Volume: 0.40
    Tachycardia: BP: 120/105(110) HR:130 Pulse Volume: 0.40
    Bradycardia: BP: 120/60(80) HR:45 Pulse Volume: 1.10
    ►Arrhythmia Simulations
    Premature Atrial Contract 1,Premature Atrial Contract 2,Premature Ventricular Contract,Atrial Fib and PVCs
    ►Respiratory Artifacts
    Spontaneous Breathing 1,Spontaneous Breathing 2,Spontaneous Breathing 3,Controlled Ventilation
    ►Neonate simulations
    User can select External or Internal Neonate;
    1#: BP: 35/15 HR: 120bpm Pulse Volume: 0.11
    2#: BP: 60/30 HR: 120bpm Pulse Volume: 0.10
    3#: BP: 80/50 HR: 120bpm Pulse Volume: 0.10
    4#: BP: 100/70 HR: 120bpm Pulse Volume: 0.10
    ►Wrist simulations
    1#: BP:120/80(93) HR: 80bpm Pulse Volume: 0.50
    2#: BP:160/100(120) HR: 80bpm Pulse Volume: 0.50
    3#: BP:80/55(63) HR: 80bpm Pulse Volume: 0.50
    ►User-Defined simulations
    Allows the operator to define blood pressure simulations.
    Systolic(mmHg) 20-250
    Diastolic(mmHg) 10-200
    Heart Rate,(bpm) 30-250
    Pulse Volume,(cc) 0.1-2.4
    ►Simulant characteristics
    The maximum pulse volume:2.4cc
    The maximum heart rate:250bpm,200bpm at pulse volume>2.00cc.
    Internal Adult cuff volume:20cc
    Internal neonate cuff volume:300cc
    Blood pressure units: mmHg,kPa
    Heart Rate Accuracy:±1BPM
    Patient Conditions:
    Weak pulse, Tachycardia,Obese,Geriatric ±1%±1BPM
    Mild exercise±1.5%±1BPM
    Strenuous exercise±3%±1BPM
    ►Display
    65k colors 4.3 inch TFT Display, brightness can be changed.
    ►Power
    AC100 - 240 V 50/60 Hz, 60 VA
    ►Environmental Conditions
    Working temperature: 15℃ to 40℃(59℉ to 104℉)
    Storage temperature: -20℃ to +65℃(-4℉ to +149℉)
    Relative humidity: < 90%,No condensation.
    ►Size (L x W x H)
    27 cm x 26.5 cm x 13.2 cm
    ►Weight
    About 4kg
    Accessories:
    Power cord
    Fuse
    User 's Manual
    ECG PATIENT SIMULATOR MS400
    Introduction
    MS400 Multiparameter Simulator is a portable device, features in small volume and light weight. It can simulate accurately 12-lead ECG, Respiration, Temperature, 2-channel IBP or 4-channel IBP. And it can be tested in where the monitor is used.
    Features
    1.Simulate 35 kinds of arrhythmia (including Atrial, Ventricular, Premature Beat and Conduction Defects) and pacemaker waveforms (including Asynchronous, Demand Occ Sinus, Demand Freq Sinus, A/V Sequential, Non Capture, Non Function).
    2.Simulate four-channel IBP data.
    3.Simulate respiration signal with adjustable respiration rate, impedance and baseline impedance, and three kinds of apnea data.
    4.Simulate four kinds of temperature data.
    5.Simulate square wave, triangle wave, pulse wave and sine wave with adjustable frequency.
    6.Simulate standard ECG calibration, adult and pediatric ECG signal.
    7.ECG waveform complied with the standard of ANSI/AAMI EC13-2002, AHA, MIT ECG database, other ECG database and user-defined waveform data stored in TF card can be displayed by the simulator and exported to the equipments to be tested.
    8.Each waveform can be displayed by sliding the 3.5'' TFT touch screen, easy to operate.
    9.Power supply: rechargeable lithium battery or linear adapter, which reduces interference.
    10.Optional operation modes: keys and touch screen.
    Parameters:
    ·ECG
    Conventional: All leads have the same voltage with the II-lead as the reference
    Amplitude: 0.5,1.0,1.5 and 2.0mV
    ECG Rate: 15,20,25,30,40,60,80,100,120,140,160,180,200,220,240,260,280,300,320,340 and 350 BPM
    ECG artifacts: 50 and 60 Hz, muscle, baseline and breathing
    The elevation of the ST segment: +0.8 to -0.8 mV, the step is 0.1 m
    ·Arrhythmia
    Atrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
    Ventricular: Vent Fib (coarse), Vent Fib (fine), PVCs 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
    Premature Beat: Atrial PAC, Nodal PNC, PVC1 LV Focus, PVC1 E LV Focus, R on T LV Focus, PVC2 RV Focus, PVC2 E RV Focus, R on T RV Focus, Multifocal PVC
    Conduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block
    ·Four IBP Channels
    he default: 00/00mmHg
    Dynamic IBP(unit: mmHg)
    Channel 1:
    Artery: 120/80
    Radial: 120/80
    Left Ventricle: 120/00
    Right Ventricle: 25/00
    Channel 2:
    Artery: 120/80
    Radial: 120/80
    Left Ventricle: 120/00
    Right Atrium(CVP): 15/10
    Right Ventricle: 25/00
    Pulmonary Artery: 25/10
    Pulmonary Wedge: 10/2
    Left Atrium: 14/4
    Channel 3:
    Artery: 120/80
    Radial: 120/80
    Left Ventricle: 120/00
    Right Atrium(CVP): 15/10
    Right Ventricle: 25/00
    Pulmonary Artery: 25/10
    Pulmonary Wedge: 10/2
    Left Atrium: 14/4
    Channel 4:
    Auto Swan-Ganz (every 15 seconds): RA(CVP), RV, PA, PAW (Pulmonary Wedge)
    Man Swan-Ganz: press ENTER key to change every time
    Static-Pressure Levels
    Channel 1: 0, 80, 160, 240, 320 and 400mmHg
    Channel 2: 0, 50, 100, 150, 200 and 250mmHg
    Channel 3: 0, 20, 40, 60, 80 and 100mmHg
    Channel 4: P4 tracks the static pressure levels of P3
    ·Respiration
    Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIN
    Impedance: 0.2, 0.5, 1.0 and 3.0 Ω
    Baseline impedance: 500, 1000, 1500, 2000Ω
    Apnea: 12 s, 22 s, 32 s
    ·Temperature
    Four temperature: 0℃(32°F), 24℃( 75°F), 37℃(98.6°F), 40℃(104°F)
    Accessories
    Standard accessories 9V/1A(CE) power adapter, an User manual, a packaging box, a plastic packaging.
    Optional accessories a power adapter(15V/1A)(UL), a power adapter(15V/1A), a temperature cable, an IBP cable, a CD disk(including a case conversion software)
    Physical characteristic
    Dimension 18.86 cm(L)×12.50 cm(W)×4.32 cm(H)
    Net weight about 1.4kg
    Buy safe products
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.
    The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that is FDA 510K Approved
    International Buyer--Please note:
    Import duties,Taxes are not included in the item price.These charges are buyers' responsibility
    We are the manufacturer of medical equipment for 17 years, the following are our main products:
    ECG /  ECG holter   EEG / EEG Holter      B-ultrasound
    Patient Monitor      Fetal doppler             Fetal Monitor
    Spo2 Monitor          Stethoscope              Medical Image...
    .
    Agent in the world!
    We are look for partners in the world now!
    Do you want  to become our agent in you conutry?
    Join US!
    Skype:xuebox3
    contec.med.mary at hotmail.com
    Only English User Manual,Please contact us if you need other language version.thank you